A&D > Weighing > LC-4101 (Aluminum)
LC-4101 (Aluminum)
| Capacity | Model No. | CAD file |
| 600 gf | LC4101-G600 | |
| 1.5 kgf | LC4101-K1.5 | |
| 3 kgf | LC4101-K003 | |
| 6 kgf | LC4101-K006 | |
| 15 kgf | LC4101-K015 |
Additional Links
| Rated capacities | 600 gf, 1.5 kgf, 3 kgf, 0 kgf, 15 kgf | |
| Maximum deadweight | 80% of rated capacity | |
| Rated output | 1 mV / V+15 / -0% | |
| Maximum safe overload | 300% of rated capacity | |
| Combined error | ±0.015% of rated output | |
| Creep | ±0.05% of rated output / hour | |
| Zero balance | 20±5% of rated output | |
| Temperature range | -10 °C to +40 °C / +14 °F to +104 °F | |
| Recommended excitation voltage |
12 V | |
| Maximum excitation voltage |
15 V | |
| Input terminal resistance | Approximately 400 Ω | |
| Output terminal resistance | 350 Ω ± 5 Ω | |
| Insulation resistance | Greater than 5000 MΩ at DC50 V | |
| Temperature effect | Zero | 0.004% of rated output / °C |
| Span | 0.0014% of rated output / Type. | |
| Platform size | 300 × 300 mm / 11.8 × 11.8 inches | |
| Cable length | 1.5 m / 59 inches | |
- Parallelogram-type construction
- Temperature compensation maintains both zero and span from -10 °C to +40 °C/+14 °F to +104 °F
- Deadweight up to 80% of capacity. Load weight and deadweight up to 180% of capacity
- Moisture proof
- Compact and lightweight
- Can be used for capacities as light as 600 g