A&D > Weighing > LCB01 / 02 / 06
| Rated capacities | 30 kgf, 60 kgf, 150 kgf, 300 kgf, 600 kgf | |
| Rated output | 0.3 mV/V±10% (LCB01/02) 0.55 mV/V±10% (LCB06) | |
| Maximum Safe overload | 150% of R.C. | |
| Combined error | 0.03% of R.O. | |
| Zero balance | 20 ± 5% of R.O. | |
| Compensated temperature range | -10 °C to 40 °C | |
| Recommended excitation voltage | 12 V | |
| Maximum excitation voltage | 15 V | |
| Input terminal resistance | 410 ± 20 Ω | |
| Output terminal resistance | 350 ± 5 Ω | |
| Insulation resistance | 5000 MΩ at DC50 V | |
| Temperature effect | Zero | 0.05% of R.O./10 °C |
| Span | 0.03% of Load /10°C Typ. | |
| Cable Length | φ7/6 m | |
| Dust & Waterproof | IP54 | |
| Maximum pan size | 400 × 400 mm (LCB01) 400 × 600 mm (LCB02) 400 × 700 mm (LCB06) |
|
- Flameproof class ExdlBT4 conformed
- Adjusted for four corners
- Tension and compression loading
- Maximum pan sizes are 400 × 400 mm (LCB01), 400 × 600 mm (LCB02) and 600 × 700 mm (LCB06)