| Rated capacities |
20 kgf, 50 kgf, 100 kgf, 200 kgf, 500 kgf, 1 tf, 2 tf, 5 tf |
| Rated output |
2 mV/V±0.5% (20 kgf, 50 kgf - 1.5 mV/V ± 0.5%) |
| Maximum safe overload |
200% of rated capacity |
| Combined error |
±0.02% of rated output |
| Creep |
±0.1 %of rated output/hour |
| Zero balance |
±2% of rated output |
| Compensated temperature range |
-10 °C to 60 °C/14 °F to +104 °F |
| Recommended excitation voltage |
12 V |
| Maximum excitation voltage |
15 V |
| Input terminal resistance |
Approximately 400 Ω |
| Output terminal resistance |
350 Ω ± 3.5 Ω |
| Insulation resistance |
Greater than 5,000 MO at DC50 V |
| Temperature effect |
Zero |
0.007% of rated output/°C |
| Span |
0.002% of rated output/°C Typ. |
| Cable length |
3 m/118 inches (1, 2 & 5 t -5 m/197 inches) |