A&D > Weighing > LCCA-21
image

LCCA-21

Stainless Steel Compact Compression Load Cell

Capacity Model No. CAD File
10.20kg (100N) LCCA21N100 CAD Download
20.39kg (200N) LCCA21N200
50.99kg (500N) LCCA21N500 CAD Download
102.0kg (1kN) LCCA21KN001

 

Safe load limit 150% of R.C.
Combined error 0.5% of R.O.
Supply voltage DC5 V ± 0.25 V less than 16mA
Load resistance More than 5 kΩ
Output voltage *1 1 V to 4 V
Zero voltage 1 V ± 0.04 V
Span voltage 2 V ± 0.01 V (1 V to 3 V)
Insulation resistance 500 MΩ / DC50 V between signal wires and load cell
Compensated temperature range 0 °C to 70 °C
Permissible temperature range -10 °C to 80 °C
Temperature effect Zero 0.6% of R.O. / 10 °C Typ.
Span 0.6% of Load / 10 °C Typ.
Frequency characteristics 100Hz (–3dB)
Cable diameter / length From load cell to amplifier φ2 mm / 2 m
From amplifier φ6 mm / 0.5 m
Dustproof / Waterproof Load cell IP64
Standard attachment holder 1 piece
Standard amplifier case holder 1 set

 

Load [% of R.C.] 0% 100% 150%
*1 Output voltage 1V 3V 4V
  • Suitable for load distribution and press pressure measurement
  • Rated capacities: 100N (10.20kg) to 1kN (102.0kg)
  • Include standard attachment holder 1 piece and amplifier case holder 1 set